TH146-N-DE 400-280-000-G 9/22/06 1/8
TH146-N-DE
Installation Guide
Non-programmable Heat Pump Controller
The TH146-N-DE electronic controller can be used to control a heat
pump system. The following devices can be connected to the con-
troller:
heat pump
auxiliary heating (furnace)
air recirculation fan
humidifier
dual-register meter (dual energy)
remote control device (for the unoccupied mode)
CT280-HP-2H1C control module
TH146 console with two wall anchors and mounting screws
AC144-03 outdoor temperature sensor (3 m or 10 ft) with
mounting clip (see section 2.7)
RC845 relay (see section 2.5)
AC146-410 plenum temperature sensor (see section 2.8)
CT241 telephone controller (see section 2.10)
Install the control module on the furnace’s electrical panel, away
from the heat source.
Install the console in the area where you wish to measure the tem-
perature and humidity. Avoid locations where there are air drafts
(e.g., top of staircase or air outlet) or stagnant air (behind a door).
Do not install the console on a wall hiding air ducts nor expose it to
direct sunlight.
NOTE: If this controller replaces an existing thermostat, the wires
that were connected to the thermostat can be used to connect the
console. The maximum wire length is 30 m (100 feet).
1) Choose a location about 5 ft. (1.5 m) above the floor on an
inside wall.
2) Loosen the captive screw under the console.
3) Detach the console from its base by pulling the bottom section.
4) Secure the base using the wall anchors and screws.
5) Connect the console to controller terminals TH and TH (no
polarity).
Connect the heat pump to the controller as follows:
Controller terminals R and C to heat pump terminals R and C
(see section 2.4)
Controller terminal Y to heat pump terminal Y
Controller terminal O/B to heat pump terminal O
Controller terminal WW to heat pump terminal WW
AC144-03 Outdoor
Temperature Sensor
TH146 User Console
CT280-HP-2H1C Control Module
1. Introduction
1.1
Applications
1.2
Supplied Parts
1.3
Accessories
2. Installation
2.1
Control Module (CT280-HP-2H1C)
2.2
User Console (TH146)
2.3
Heat Pump
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - TH146-N-DE

TH146-N-DE 400-280-000-G 9/22/06 1/8TH146-N-DEInstallation GuideNon-programmable Heat Pump ControllerThe

Page 2

TH146-N-DE 400-280-000-G 9/22/06 2/8• Controller terminal L to heat pump terminal L • Controller terminal

Page 3 - 3.1.3 Keypad Lock (SW3)

TH146-N-DE 400-280-000-G 9/22/06 3/83.1.1 Backlight (SW1)BL ON: The screen is always backlit.AUTO: The sc

Page 4 - Configuration Menu

TH146-N-DE 400-280-000-G 9/22/06 4/8Configuration MenuItem Parameters Display Options Default Description

Page 5

TH146-N-DE 400-280-000-G 9/22/06 5/8Connection Diagram — New InstallationTH146AC144-03AC146-410CT241Humid

Page 6

TH146-N-DE 400-280-000-G 9/22/06 6/8Connection Diagram — Add-on InstallationTH14624 V TransformerDual Ene

Page 7

TH146-N-DEUser’s GuideNon-programmable Heat Pump ControllerTH146-N-DE 400-280-000-G 9/22/06 7/8Press MODE

Page 8 - 8. Support

TH146-N-DE 400-280-000-G 9/22/06 8/82) Set the humidity level or offset using the buttons.• humidity le

Comments to this Manuals

No comments